 Description                                                                                                                                               

Details -

Adobe (PDF)

 

Details -

AutoCad (DWG)

 

Details -

BIM  (RVT)

 

Details -

3D (PDF)
 THERMOCROMEX OVER CMU, POURED IN PLACE AND TILT WALL 
Masonry Substrate
 1.01  1.01a  1.01 RVT
 1.01-3D
Smooth Concrete Substrate (Poured in Place Concrete or Tilt Wall)  1.02  1.02a  1.02 RVT
 1.02-3D 
CMU Wall - Casing Bead at Concrete Foundation  1.03  1.03a  1.03 RVT
 1.03-3D
CMU Wall - Foundation Screed at Concrete Foundation  1.04  1.04a  1.04 RVT
 1.04-3D
PIP/Tilt Wall - Casing Bead at Concrete Foundation  1.05  1.05a  1.05 RVT
 1.05-3D
PIP/Tilt Wall - Foundation Screed at Concrete Foundation
 1.06  1.06a  1.06 RVT
 1.06-3D
Two Dissimilar Substrates  1.07  1.07a  1.07 RVT
 1.07-3D
Construction Joint in Tilt Wall  1.08  1.08a  1.08 RVT  1.08-3D
Construction Joint in Tilt Wall with Two Piece Expansion Joint  1.09  1.09a  1.09 RVT  1.09-3D
Two Piece Expansion Joint at Control Joint in CMU Wall  1.10  1.10a  1.10 RVT  1.10-3D
Control Joint with Casing Bead on CMU Wall  1.11  1.11a  1.11 RVT  1.11-3D
       
 THERMOCROMEX OVER FRAME AND SHEATHING
 Sheathed Framing Substrate  2.01  2.01a  2.01 RVT
 2.01-3D
 Horizontal or Vertical Expansion Joint  2.02  2.02a  2.02 RVT
 2.02-3D
 Horizontal Expansion Joint
 2.03  2.03a  2.03 RVT  2.03-3D
 Expansion Joint Intersection  2.04  2.04a  2.04 RVT  2.04-3D
 Expansion Joint at Casing Bead or Foundation Screed
 2.05  2.05a  2.05 RVT   2.05-3D
 Horizontal Flashing and Expansion Joint
 2.06  2.06a  2.06 RVT  2.06-3D
 Termination at Concrete Foundation
 2.07  2.07a  2.07 RVT  2.07-3D
 Termination at Storefront Window - Head & Sill  2.08  2.08a  2.08 RVT  2.08-3D
 Termination at Storefront Window - Jamb  2.09  2.09a  2.09 RVT  2.09-3D
 Termination at Flashing Nail on Window  2.10  2.10a  2.10 RVT  2.10-3D
 Storefront Window - Set back  2.11  2.11a  2.11 RVT  2.11-3D
 Termination at Wood Window  2.12  2.12a  2.12 RVT  2.12-3D
 Inside Corner
 2.13  2.13a  2.13 RVT  2.13-3D
 Inside Corner Control Joint
 2.14  2.14a  2.14 RVT  2.14-3D
 Outside Corner  2.15  2.15a  2.15 RVT  2.15-3D
 Termination at Roof  2.16  2.16a  2.16 RVT  2.16-3D
 Termination at Roof/Wall  2.17  2.17a  2.17 RVT  2.17-3D
 Termination at Sloped Roof  2.18  2.18a  2.18 RVT  2.18-3D
 Termination at Parapet/Wall Intersection  2.19  2.19a  2.19 RVT  2.19-3D
 Soffit with Continuous Vent
 2.20  2.20a  2.20 RVT  2.20-3D
 Soffit/Fascia Intersection
 2.21  2.21a  2.21 RVT  2.21-3D
 Termination at Deck Flashing  2.22  2.22a  2.22 RVT  2.22-3D
 Sloped Sill  2.23  2.23a N/A N/A 
 Termination at EIFS/Lap Siding  2.24  2.24a  2.24 RVT  2.24-3D
 Hose Bib Penetration
 2.25  2.25a  2.25 RVT  2.25-3D
 Pipe Railing Attachment
 2.26  2.26a  2.26 RVT  2.26-3D
 Parapet Flashing
 2.27  2.27a  2.27 RVT  2.27-3D

 Two Dissimilar Substrates 

 2.28  2.28a  2.28 RVT  2.28-3D
 Termination at Hollow Metal Door Frame  2.29  2.29a  2.29 RVT  2.29-3D
 Termination at Inset Door Frame  2.30  2.30a  2.30 RVT  2.30-3D
 THERMOCROMEX OVER ICF
 ICF  3.01  3.01a

 3.01 RVT

 3.01-3D
 Expansion Joint
 3.02  3.02a  3.02 RVT  3.02-3D
 Foundation Screed at Concrete Foundation  3.03  3.03a  3.03 RVT  3.03-3D
 Grade Termination
 3.04  3.04a  3.04 RVT  3.04-3D
 Cantilever Concrete Deck Termination
 3.05  3.05a  3.05 RVT  3.05-3D
 Parapet Termination
 3.06  3.06a  3.06 RVT  3.06-3D
 Commercial Window Sill With Window Buck  3.07  3.07a  3.07 RVT  3.07-3D
 Commercial Window Sill Without Window Buck  3.08  3.08a  3.08 RVT  3.08-3D
 Window Head and Jamb With Window Buck Removed
 3.09  3.09a  3.09 RVT  3.09-3D
 Window Head and Jamb With Permanent Metal or Vinyl Window Buck  3.10  3.10a  3.10 RVT  3.10-3D
 Window Head and Jamb for Window Buck on Residential Construction  3.11  3.11a  3.11 RVT  3.11-3D
 Residential Window Sill  3.12  3.12a  3.12 RVT  3.12-3D
         
 THERMOCROMEX OVER EPS TRM
 EPS Trim  4.01

 4.01a

 4.01 RVT
 4.01-3D
         
 THERMOCROMEX OVER AAC LIGHT WEIGHT CONCRETE
 Exterior Wall
 5.01  5.01a  5.01 RVT
 5.01-3D
 Exterior Wall Reinf. Loc. (Panel)
 5.02  5.02a  5.02 RVT  5.02-3D
 Exterior Wall Reinf. Loc. (Block)
 5.03  5.03a  5.03 RVT  5.03-3D
 Floor Panel Span Transition (Panel)
 5.04  5.04a  5.04 RVT  5.04-3D
 Floor Panel Span Transition (Block)  5.05  5.05a  5.05 RVT  5.05-3D
 Floor/Roof Panels End Brg. (Panel)  5.06  5.06a  5.06 RVT  5.06-3D
 Floor/Roof Panels End. Brg. (Block)  5.07  5.07a  5.07 RVT  5.07-3D
 Electrical Service  5.08  5.08a   5.08 RVT  5.08-3D
 Typical Reinforced Wall Panel
 5.09  5.09a  5.09 RVT  5.09-3D

 

NOTE: All components designated in drawings shall be designed, detailed and engineered by representatives of the Architect, owner or contractor in compliance with model codes, architectural and engineering requirements pertaining to specific building projects. Southwest Progressive Enterprises Inc., makes no representation regarding conformity of its suggestions to model building codes, engineering criteria, specific applications or project locations. Southwest Progressive Enterprises Inc., makes no warranty, expressed or implied as to the architectural design, engineering, or workmanship of projects using Thermocromex.