Thermocromex Installation Details - Table of Contents

Description                                                                                                                                               

Details

Adobe

(PDF)

Details

AutoCad

(DWG)

Details

BIM

(RVT)

Details

3D (PDF)

 

 

 THERMOCROMEX OVER CMU, POURED IN PLACE AND TILT WALL 
Masonry Substrate
 1.01  1.01a  1.01 RVT
 1.01-3D
Smooth Concrete Substrate (Poured in Place Concrete or Tilt Wall)  1.02  1.02a  1.02 RVT
 1.02-3D 
CMU Wall - Casing Bead at Concrete Foundation  1.03  1.03a  1.03 RVT
 1.03-3D
CMU Wall - Foundation Screed at Concrete Foundation  1.04  1.04a  1.04 RVT
 1.04-3D
PIP/Tilt Wall - Casing Bead at Concrete Foundation  1.05  1.05a  1.05 RVT
 1.05-3D
PIP/Tilt Wall - Foundation Screed at Concrete Foundation
 1.06  1.06a  1.06 RVT
 1.06-3D
Two Dissimilar Substrates  1.07  1.07a  1.07 RVT
 1.07-3D
Construction Joint in Tilt Wall  1.08  1.08a  1.08 RVT  1.08-3D
Construction Joint in Tilt Wall with Two Piece Expansion Joint  1.09  1.09a  1.09 RVT  1.09-3D
Two Piece Expansion Joint at Control Joint in CMU Wall  1.10  1.10a  1.10 RVT  1.10-3D
Control Joint with Casing Bead on CMU Wall  1.11  1.11a  1.11 RVT  1.11-3D
       
 THERMOCROMEX OVER FRAME AND SHEATHING
 Sheathed Framing Substrate  2.01  2.01a  2.01 RVT
 2.01-3D
 Horizontal or Vertical Expansion Joint  2.02  2.02a  2.02 RVT
 2.02-3D
 Horizontal Expansion Joint  2.03  2.03a  2.03 RVT  2.03-3D
 Expansion Joint Intersection  2.04  2.04a  2.04 RVT  2.04-3D
 Expansion Joint at Casing Bead or Foundation Screed  2.05  2.05a  2.05 RVT   2.05-3D
 Horizontal Flashing and Expansion Joint  2.06  2.06a  2.06 RVT  2.06-3D
 Termination at Concrete Foundation  2.07   2.07a  2.07 RVT  2.07-3D
 Termination at Storefront Window - Head & Sill  2.08  2.08a  2.08 RVT  2.08-3D
 Termination at Storefront Window - Jamb  2.09  2.09a  2.09 RVT  2.09-3D
 Termination at Flashing Nail on Window  2.10  2.10a  2.10 RVT  2.10-3D
 Storefront Window - Set back  2.11  2.11a  2.11 RVT  2.11-3D
 Termination at Wood Window  2.12  2.12a  2.12 RVT  2.12-3D
 Inside Corner  2.13  2.13a  2.13 RVT  2.13-3D
 Inside Corner Control Joint
 2.14  2.14a  2.14 RVT  2.14-3D
 Outside Corner  2.15  2.15a  2.15 RVT  2.15-3D
 Termination at Roof  2.16  2.16a  2.16 RVT  2.16-3D
 Termination at Roof/Wall  2.17  2.17a  2.17 RVT  2.17-3D
 Termination at Sloped Roof  2.18  2.18a  2.18 RVT  2.18-3D
 Termination at Parapet/Wall Intersection  2.19  2.19a  2.19 RVT  2.19-3D
 Soffit with Continuous Vent
 2.20  2.20a  2.20 RVT  2.20-3D
 Soffit/Fascia Intersection
 2.21  2.21a  2.21 RVT  2.21-3D
 Termination at Deck Flashing  2.22  2.22a  2.22 RVT  2.22-3D
 Sloped Sill  2.23  2.23a N/A N/A 
 Termination at EIFS/Lap Siding  2.24  2.24a  2.24 RVT  2.24-3D
 Hose Bib Penetration  2.25  2.25a  2.25 RVT  2.25-3D
 Pipe Railing Attachment  2.26  2.26a  2.26 RVT  2.26-3D
 Parapet Flashing  2.27  2.27a  2.27 RVT  2.27-3D

 Two Dissimilar Substrates 

 2.28  2.28a  2.28 RVT  2.28-3D
 Termination at Hollow Metal Door Frame  2.29  2.29a  2.29 RVT  2.29-3D
 Termination at Inset Door Frame  2.30  2.30a  2.30 RVT  2.30-3D

THERMOCROMEX OVER FRAME AND SHEATHING WITH INSULATION BOARD
 Sheathed Framing Substrate with Insulation Board  2.01 IB  2.01a IB 2.01 RVT IB  2.01-3D
 Horizontal or Vertical Expansion Joint with Insulation Board  2.02 IB  2.02a IB

2.02 RVT IB                              

2.02-3D

 Horizontal Expansion Joint with Insulation Board

 2.03 IB  2.03a IB  2.03 RVT IB
2.03-3D
 Expansion Joint Intersection with Insulation Board  2.04 IB  2.04a IB  2.04 RVT IB 2.04-3D
 Expansion Joint at Casing Bead or Foundation Screed with Insulation Board  2.05 IB  2.05a IB  2.05 RVT IB 2.05-3D

 Horizontal Flashing and Expansion Joint with Insulation Board

 2.06 IB  2.06a IB  2.05 RVT IB 2.05-3D
 Termination at Concrete Foundation with Insulation Board  2.07 IB  2.07a IB  2.07 RVT IB 2.07-3D
 Termination at Storefront Window - Head & Sill with Insulation Board  2.08 IB  2.08a IB  2.08 RVT IB 2.08-3D
 Termination at Storefront Window - Jamb with Insulation Board  2.09 IB  2.09a IB  2.09 RVT IB 2.09-3D
 Termination at Flashing Nail on Window with Insulation Board  2.10 IB  2.10a IB  2.10 RVT IB 2.10-3D
 Storefront Window - Set back with Insulation Board  2.11 IB  2.11a IB  2.11 RVT IB 2.11-3D
 Termination at Wood Window with Insulation Board  2.12 IB  2.12a IB  2.12 RVT IB 2.12-3D
 Inside Corner with Insulation Board  2.13 IB  2.13a IB  2.13 RVT IB 2.13-3D
 Inside Corner Control Joint with Insulation Board  2.14 IB  2.14a IB  2.14 RVT IB 2.14-3D
 Outside Corner with Insulation Board  2.15 IB  2.15a IB  2.15 RVT IB 2.15-3D
 Termination at Roof with Insulation Board  2.16 IB  2.16a IB  2.16 RVT IB 2.16-3D
 Termination at Roof/Wall with Insulation Board  2.17 IB  2.17a IB  2.17 RVT IB 2.17-3D
 Termination at Sloped Roof with Insulation Board  2.18 IB  2.18a IB  2.18 RVT IB 2.18-3D
 Termination at Parapet/Wall Intersection with Insulation Board  2.19 IB  2.19a IB  2.19 RVT IB 2.19-3D
 Soffit with Continuous Vent with Insulation Board
 2.20 IB  2.20a IB  2.20 RVT IB 2.20-3D
 Soffit/Fascia Intersection with Insulation Board
 2.21 IB  2.21a IB  2.21 RVT IB 2.21-3D
 Termination at Deck Flashing with Insulation Board  2.22 IB  2.22a IB  2.22 RVT IB 2.22-3D
 Sloped Sill with Insulation Board  2.23 IB  2.23a IB N/A N/A   
 Termination at EIFS/Lap Siding with Insulation Board  2.24 IB  2.24a IB  2.24 RVT IB 2.24-3D
 Hose Bib Penetration with Insulation Board
 2.25 IB  2.25a IB  2.25 RVT IB 2.25-3D
 Pipe Railing Attachment with Insulation Board
 2.26 IB  2.26a IB  2.26 RVT IB 2.26-3D
 Parapet Flashing with Insulation Board
 2.27 IB  2.27a IB  2.27 RVT IB 2.27-3D

 Two Dissimilar Substrates with Insulation Board

 2.28 IB  2.28a IB  2.28 RVT IB 2.28-3D
 Termination at Hollow Metal Door Frame with Insulation Board  2.29 IB  2.29a IB  2.29 RVT IB 2.29-3D
 Termination at Inset Door Frame with Insulation Board  2.30 IB  2.30a IB  2.30 RVT IB 2.30-3D
 

 THERMOCROMEX INTERIOR APPLICATION

 Interior Framing with Durock Sheathing  2.31  2.31a  2.31 RVT  2.31-3D
 
 THERMOCROMEX OVER ICF
 ICF  3.01  3.01a

 3.01 RVT

 3.01-3D
 Expansion Joint
 3.02  3.02a  3.02 RVT  3.02-3D
 Foundation Screed at Concrete Foundation  3.03  3.03a  3.03 RVT  3.03-3D
 Grade Termination
 3.04  3.04a  3.04 RVT  3.04-3D
 Cantilever Concrete Deck Termination
 3.05  3.05a  3.05 RVT  3.05-3D
 Parapet Termination
 3.06  3.06a  3.06 RVT  3.06-3D
 Commercial Window Sill With Window Buck  3.07  3.07a  3.07 RVT  3.07-3D
 Commercial Window Sill Without Window Buck  3.08  3.08a  3.08 RVT  3.08-3D
 Window Head and Jamb With Window Buck Removed
 3.09  3.09a  3.09 RVT  3.09-3D
 Window Head and Jamb With Permanent Metal or Vinyl Window Buck  3.10  3.10a  3.10 RVT  3.10-3D
 Window Head and Jamb for Window Buck on Residential Construction  3.11  3.11a  3.11 RVT  3.11-3D
 Residential Window Sill  3.12  3.12a  3.12 RVT  3.12-3D
         
 THERMOCROMEX OVER EPS TRM
 EPS Trim  4.01

 4.01a

 4.01 RVT
 4.01-3D
         
 THERMOCROMEX OVER AAC LIGHT WEIGHT CONCRETE
 Exterior Wall
 5.01  5.01a  5.01 RVT
 5.01-3D
 Exterior Wall Reinf. Loc. (Panel)
 5.02  5.02a  5.02 RVT  5.02-3D
 Exterior Wall Reinf. Loc. (Block)
 5.03  5.03a  5.03 RVT  5.03-3D
 Floor Panel Span Transition (Panel)
 5.04  5.04a  5.04 RVT  5.04-3D
 Floor Panel Span Transition (Block)  5.05  5.05a  5.05 RVT  5.05-3D
 Floor/Roof Panels End Brg. (Panel)  5.06  5.06a  5.06 RVT  5.06-3D
 Floor/Roof Panels End. Brg. (Block)  5.07  5.07a  5.07 RVT  5.07-3D
 Electrical Service  5.08  5.08a   5.08 RVT  5.08-3D
 Typical Reinforced Wall Panel
 5.09  5.09a  5.09 RVT  5.09-3D

 

 

NOTE: All components designated in drawings shall be designed, detailed and engineered by representatives of the Architect, owner or contractor in compliance with model codes, architectural and engineering requirements pertaining to specific building projects. Southwest Progressive Enterprises Inc., makes no representation regarding conformity of its suggestions to model building codes, engineering criteria, specific applications or project locations. Southwest Progressive Enterprises Inc., makes no warranty, expressed or implied as to the architectural design, engineering, or workmanship of projects using Thermocromex.